HP HPE2-T37: Using HPE OneView exam is a professional-level certification exam that is intended for IT professionals who have experience in managing HPE infrastructure. HPE2-T37 exam is designed to test the candidate's knowledge and skills in using HPE OneView to manage HPE infrastructure. Candidates who pass the exam will be recognized as certified professionals who have the skills and knowledge to use HPE OneView effectively.
HPE2-T37 exam is intended for IT professionals who have experience with HPE infrastructure and want to demonstrate their skills in using HPE OneView. HPE2-T37 exam is also suitable for IT professionals who are responsible for managing HPE infrastructure and want to improve their skills in using HPE OneView. Passing the HPE2-T37 exam will demonstrate your expertise in using HPE OneView and will help you advance in your career.
NEW QUESTION # 36
You have to move a server profile from a server to the other server. What must be done prior server profile migration?
- A. Source system has to be placed in a maintenance mode.
- B. Target server has to be placed in a maintenance mode.
- C. Target system must be powered off.
- D. Source server has to be powered on.
Answer: C
Explanation:
Before moving a server profile to another server in HPE OneView, the target system must be powered off.
This is required to ensure that the profile settings, including firmware, BIOS settings, and connectivity configurations, are applied correctly without any conflicts. Powering off the target server prevents any operational disruptions and ensures a smooth transition of the server profile.
NEW QUESTION # 37
You need to make sure that server ports connected to this network cannot communicate with each other within the logical interconnect. Click the option within the network definition that will allow you to configure the required parameter.
Answer:
Explanation:
NEW QUESTION # 38
Click the option that will allow you to disable virtual MAC addresses or generate a new pool of virtual Worldwide Names.
Answer:
Explanation:
NEW QUESTION # 39
You want to enable HPE Remote Support within HPE OneView.
Which servers will be covered with HPE Remote Support once enabled?
- A. Only HPE Synergy Compute Modules with a server profile applied.
- B. Any servers under warranty or active service contract.
- C. Any Gen8, Gen9 and Gen10 servers managed using HPE OneView.
- D. Any server except HPE Superdome Flex and HPE Superdome Flex 280.
Answer: B
NEW QUESTION # 40
HOTSPOT
Click option that will allow you to select a FlexNIC function for the specified connection.
Answer:
Explanation:
Explanation:
Graphical user interface
Description automatically generated
NEW QUESTION # 41
Which statement about the volume template is true?
- A. Users will be able to change sharing type and volume capacity
- B. A volume created using this template mil not support snapshots
- C. A volume created using this template will not support deduplication
- D. Users will be able to select storage pool during volume creation
Answer: D
NEW QUESTION # 42
Which statement regarding HPE GreenLake for Compute Ops Management - OneView Edition requirements is true?
- A. It supports HPE ProLiant G6 and newer systems regardless of the OS installed.
- B. It supports HPE OneView instances from version 8.40 or newer.
- C. It is available for customers that have more than three HPE Synergy Frames.
- D. It can be used tree of charge for the HPE Synergy platform because the licenses are included.
Answer: D
Explanation:
HPE GreenLake for Compute Ops Management - OneView Edition can be used free of charge for the HPE Synergy platform because the licenses are included. This means that customers using HPE Synergy systems receive the benefits of HPE OneView management capabilities without additional licensing costs.
* Option A is incorrect because HPE OneView versions do not align with version 8.40; as of the knowledge cutoff in 2023, HPE OneView versions are up to 6.x.
* Option C is incorrect because the availability of the service is not restricted to customers with more than three HPE Synergy frames.
* Option D is incorrect because HPE ProLiant G6 servers are not supported by HPE OneView; support typically begins from Gen8 servers onward.
NEW QUESTION # 43
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.
Answer:
Explanation:
NEW QUESTION # 44
You want to update the firmware for only two HPE Synergy Virtual Connect SE 32Gb FC Modules of a large environment.
From which level must this procedure be initiated?
- A. Server Profile
- B. Logical Interconnect Group
- C. Logical Enclosure
- D. Logical Interconnect
Answer: D
Explanation:
Reference:
https://cdn.cnetcontent.com/syndication/feeds/hp-ent/inline-content/S7/C/D/CD7C939EFCECEA1124D03234E6E25BC684192820_source.PDF
NEW QUESTION # 45
For each feature. indicate whether it is available with both hpe oneview Standard and hpe oneview Advanced licenses, or only with an hpe oneview Advanced license.
Answer:
Explanation:

NEW QUESTION # 46
After replacing a failed Compute Module, you notice the server profile Is not automatically assigned to the replaced server hardware. What can cause this issue?
- A. The enclosure group has to be updated to match the original enclosure group.
- B. Server profile affinity is configured to Device Day + server hardware.
- C. IL0 firmware of the replacement server is different than firmware in broken server.
- D. The replacement server has more memory or CPUs than broken machine.
Answer: C
NEW QUESTION # 47
Which operation can be performed using HPE OneView for VMware vCenter Server?
- A. Create a new VMware cluster within vCenter Server.
- B. Create a new distributed switch for cluster connectivity.
- C. Deploy a new cluster node using OS Deployment Plan.
- D. Configure VMware cluster properties for HA and DRS.
Answer: C
NEW QUESTION # 48
Refer to the exhibit.
Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?
- A. Firmware on the master modules is too low to support highly available setup.
- B. A dedicated license must be added to HPE OneView to enable this feature.
- C. Some master modules only support a redundant setup.
- D. There are not sufficient frames for highly available setup.
Answer: C
NEW QUESTION # 49
Which statement about logical JBODs configured using KPE OneView and D3940 Storage Modules is true?
- A. A logical JBOD lifecycle can be associated with a server profile lifecycle and drives can be securely erased.
- B. A logical JBOD cannot be created during server profile creation and must be prepared in advance
- C. Different types of the drives can be used within a logical JBOD as long as they have the same capacity
- D. Logical JBOD functionality must be enabled on the Enclosure Group level by a storage administrator
Answer: B
NEW QUESTION # 50
Your customer wants to use HPE OneView for VMware vCenter Server to simplify management of their VMware cluster running on HPE Synergy. The customer is concerned with the cost of additional licenses.
How will you explain licensing rules for this product?
- A. As long as the customer has HPE OneVtew Global Dashboard deployed, HPE OneView for VMware vCenter Server does not require any additional licenses.
- B. If the number of the HPE Synergy Compute Modules installed in HPE Synergy frame is less than 10, no license is required to use HPE OneView tor VMware vCenter Server.
- C. One HPE OneView for VMware vCenter Server license is required per HPE Synergy frame if more than 10 Compute Modules are installed in the frame.
- D. As long as the server is managed using HPE OneView. the customer can use HPE OneView for VMware vCenter Server without additional licenses.
Answer: D
NEW QUESTION # 51
Refer to the exhibit.
Which statement about server connections is true?
- A. Ethernet connection is configured to boot from PXE
- B. Storage array is connected directly to an HPE Synergy frame
- C. LACP on downlinks is configured for Ethernet connection
- D. All connections within the server profile are using physical IDs
Answer: A
NEW QUESTION # 52
Refer to the exhibit.
Your customer created multiple networks in HPE OneView, but only Eth-1 is available to be used within a server profile. What is a likely cause of this situation?
- A. The other networks are not added to the Logical Interconnect Group configuration.
- B. The other networks are configured with a purpose other than General or Management.
- C. The other networks are not configured with the required Smart Link parameter.
- D. The other networks have Private Network' selected, which hides them from Compute Modules.
Answer: D
NEW QUESTION # 53
Which types of support dump can be created using HPE OneView? (Select two.)
- A. Maintenance console support dump
- B. Firmware deployment support dump
- C. Appliance support dump
- D. Enclosure group support dump
- E. Logical enclosure support dump
Answer: A,E
NEW QUESTION # 54
A customer has to deploy 21 HPE Synergy Compute Modules in a boot from SAN setup. How this task can be simplified while keeping the profile consistent?
- A. single SAN volume can be created and utilized by all HPE Synergy Compute Modules.
- B. An existing volume can be replicated automatically when creating a server profile.
- C. Boot volumes can be prepared in advance and later presented as shared volumes to the Compute Modules.
- D. Boot volumes can be created on demand and defined in the server profile template.
Answer: D
NEW QUESTION # 55
Refer to the exhibit.
Which statement about the logical interconnect shown is true?
- A. For FC uplink sets, an additional uplink from second module should be added for redundancy.
- B. FC uplinks are not supported and will be converted to FCoE or RoCE uplinks.
- C. Additional uplink ports can be added to ETH-Uplink to increase available bandwidth.
- D. The maximum supported number of the internal networks for logical interconnect is configured.
Answer: B
NEW QUESTION # 56
Your customer wants to add second HPE Synergy frame to an existing logical enclosure. How it can be achieved?
- A. Customer has to create new enclosure group and re-parent an existing logical enclosure to the new enclosure group.
- B. Customer has to join new enclosure to the management ring and modify logical interconnect group to add new frame.
- C. Customer has to delete an existing logical enclosure, create new enclosure group and re-create logical enclosure.
- D. Customer has to use HPE OneView server migration feature to migrate new servers to an existing logical enclosure.
Answer: B
Explanation:
To add a second HPE Synergy frame to an existing logical enclosure, the customer needs to join the new enclosure to the management ring and modify the Logical Interconnect Group (LIG) to add the new frame. This process involves:
* Joining the New Enclosure to the Management Ring: Physically connect the new Synergy frame to the existing frames using the Frame Link Modules (FLMs). This extends the management network, allowing HPE OneView to discover and manage the new enclosure.
* Modifying the Logical Interconnect Group (LIG): Update the existing LIG to include the interconnect modules of the new frame. This ensures that network configurations are consistent across all frames in the logical enclosure.
* Adding the Enclosure to the Logical Enclosure: In HPE OneView, add the new enclosure to the existing logical enclosure. This integrates the new frame into the managed environment, allowing server profiles and resources to be utilized seamlessly.
NEW QUESTION # 57
Refer to the exhibit.
A customer complains that firmware compliance is empty. The customer confirmed that Synergy Service Pack is uploaded to the HPE OneView repository. How should you respond?
- A. The firmware repository service must be restarted using maintenance connection.
- B. The firmware repository is not defined within firmware compliance report.
- C. All of the components are up to date and compliant with firmware baseline.
- D. The refresh procedure must be performed on each logical enclosure to refresh firmware.
Answer: A
NEW QUESTION # 58
Which of the following is a characteristic of the RoCE network type?
- A. It is always configured as a private network.
- B. It has Quality of Service enabled by default.
- C. It has smart link enabled at all times.
- D. It must be a tagged network.
Answer: D
Explanation:
A key characteristic of the RoCE (RDMA over Converged Ethernet) network type is that it must be a tagged network. RoCE requires VLAN tagging to segregate traffic and ensure proper delivery of RDMA services over Ethernet networks. Tagging facilitates the identification and handling of RoCE traffic by the network infrastructure.
* Option C (Correct): RoCE networks require VLAN tagging to function correctly.
* Option A: Quality of Service (QoS) is important for performance but is not enabled by default.
* Option B: RoCE networks are not inherently private; they can be configured according to requirements.
* Option D: Smart Link is not necessarily enabled for RoCE networks by default.
NEW QUESTION # 59
Your customer built a sever profile for HPE Synergy Gen 10 server and configured boot mode to Legacy BIOS. Which feature Is not available for this Compute Module?
- A. Secure boot
- B. Workload profile
- C. Boot from SAN
- D. BIOS management
Answer: A
NEW QUESTION # 60
Your customer runs VMware ESXi on an HPE Synergy platform. The ESXi systems must have access to 50 VLANs initially. However, this is a dynamic environment, and more VLANs will be added in the future.
They want to add more networks for virtual machines, but they do not want to modify the HPE Virtual Connect configuration.
Which type of the network should the customer define?
- A. Untagged
- B. Internal
- C. Tunnel
- D. Tagged
Answer: C
NEW QUESTION # 61
......